Not health advice. Contact your local water utility for concerns.
Data from EPA Water Quality Reports. For official information, contact your water utility or health department.
EPA records for LIVINGSTON TWP DIV OF WATER • Updated October 2026
Grade D — based on EPA compliance records, lead testing and PFAS monitoring
LIVINGSTON TWP DIV OF WATER has notable problems in EPA's records — health-based violations, elevated lead or PFAS above the federal limit. A certified filter is a reasonable precaution.
Livingston Township, NJ tap water is legal to drink but grades D on EPA's records, mainly because of PFOA or PFOS measured at or above the 4 ppt federal limit in 2023–2025 EPA sampling. A certified filter matched to that finding is a reasonable precaution.
Livingston Township, NJ tap water is legal to drink but grades D on EPA's records, mainly because of PFOA or PFOS measured at or above the 4 ppt federal limit in 2023–2025 EPA sampling. A certified filter matched to that finding is a reasonable precaution.
LIVINGSTON TWP DIV OF WATER's most recent Lead and Copper Rule result (2022-01-01 to 2024-12-31) was 4.18 ppb at the 90th percentile, below EPA's 15 ppb action level. Because lead usually comes from service lines and household plumbing, homes built before 1986 should still test at the tap.
Yes. EPA's UCMR5 sampling (2024-08-05 to 2025-05-27) detected PFBA, PFBS, PFHpA, PFHxA, PFHxS, PFOA, PFOS, PFPeA, with PFOA or PFOS at or above the 4 ppt federal MCL. Reverse osmosis and certified activated-carbon filters reduce PFAS.
LIVINGSTON TWP DIV OF WATER has 37 violations on file since 2016: 0 health-based in the last five years and 9 monitoring or reporting violations in that window. Monitoring violations are paperwork lapses, not measured contamination.
LIVINGSTON TWP DIV OF WATER reports purchased surface water as its primary source and serves about 27,391 people (EPA PWSID NJ0710001).
We recommend one. Reverse osmosis or a PFAS-certified carbon filter addresses the PFAS result.
Compare filter options for your Livingston Township tap water
PFOA or PFOS was measured at or above EPA's 4 ppt limit in Livingston Township's UCMR5 sampling.
See the filters matched to Livingston Township's EPA results → — which certification actually removes what was found here, and what it does not touch.
Unsure which contaminants to treat? Compare home kits and certified lab testing before buying.
Amazon. We may earn a commission, at no extra cost to you.
LIVINGSTON TWP DIV OF WATER · SDWIS records since 2016 · 5-year window starts 2021-10-16
EPA records no health-based violations for this system in the last five years. The 9 violations on file in that window are monitoring or reporting paperwork issues, not measured contaminant exceedances.
| Violation | Category | Compliance period | Status |
|---|---|---|---|
| Report Sample Result/Fail Monitor (RTCR)Revised Total Coliform Rule | Reporting | 2026-03-11 | Resolvedreturned 2026-02-24 |
| Lead Consumer NoticeLead and Copper Rule | Monitoring & reporting | 2024-12-30 | Resolvedreturned 2025-07-01 |
| Monitoring of Treatment (SWTR-Filter)Surface Water Treatment Rule | Monitoring & reporting | 2024-08-01 → 2024-08-31 | Resolvedreturned 2024-08-20 |
| Monitoring, RegularCYANIDE | Monitoring & reporting | 2023-01-01 → 2025-12-31 | Archived |
| Monitoring, RegularCYANIDE | Monitoring & reporting | 2023-01-01 → 2025-12-31 | Archived |
| Consumer Confidence Report Complete Failure to ReportConsumer Confidence Rule | Other | 2022-07-01 | Resolvedreturned 2022-08-01 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2022-04-01 → 2022-06-30 | Resolvedreturned 2022-06-30 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2022-04-01 → 2022-06-30 | Resolvedreturned 2022-06-30 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2022-04-01 → 2022-06-30 | Resolvedreturned 2022-06-30 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2022-04-01 → 2022-06-30 | Resolvedreturned 2022-06-30 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2021-07-01 → 2021-09-30 | Resolvedreturned 2021-09-30 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2021-07-01 → 2021-09-30 | Resolvedreturned 2021-09-30 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2021-04-01 → 2021-06-30 | Resolvedreturned 2021-06-30 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2021-04-01 → 2021-06-30 | Resolvedreturned 2021-06-30 |
| Consumer Confidence Report Complete Failure to ReportConsumer Confidence Rule | Other | 2020-07-01 | Resolvedreturned 2020-07-20 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2020-04-01 → 2020-06-30 | Resolvedreturned 2020-06-30 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2020-04-01 → 2020-06-30 | Resolvedreturned 2020-06-30 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2020-04-01 → 2020-06-30 | Resolvedreturned 2020-06-30 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2020-04-01 → 2020-06-30 | Resolvedreturned 2020-06-30 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2020-01-01 → 2020-03-31 | Resolvedreturned 2020-03-31 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2020-01-01 → 2020-03-31 | Resolvedreturned 2020-03-31 |
| Monitoring, RegularETHYLENE DIBROMIDE | Monitoring & reporting | 2020-01-01 → 2020-03-31 | Resolvedreturned 2020-03-31 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2020-01-01 → 2020-03-31 | Resolvedreturned 2020-03-31 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2020-01-01 → 2020-03-31 | Resolvedreturned 2020-03-31 |
| Monitoring, Regular1,2-DIBROMO-3-CHLOROPROPANE | Monitoring & reporting | 2020-01-01 → 2020-03-31 | Resolvedreturned 2020-03-31 |
Showing 25 of 37 violations on file. Full record on EPA ECHO.
Source: ECHO SDWA bulk download (SDWA_VIOLATIONS_ENFORCEMENT.csv, SDWIS 2026Q2, file dated 2026-07-09, fetched 2026-09-06)
EPA Lead and Copper Rule 90th-percentile results reported by LIVINGSTON TWP DIV OF WATER
Well below the 15 ppb action level. In the most recent monitoring period on file (2022-01-01 to 2024-12-31), 90% of the homes LIVINGSTON TWP DIV OF WATER sampled had lead at or below 4.18 ppb.
EPA's action level is 15 ppb (dropping to 10 ppb under the 2024 Lead and Copper Rule Improvements). There is no safe level of lead; the 90th-percentile figure describes the system, not your tap — homes with lead service lines or pre-1986 plumbing can be higher.
| Monitoring period | Lead 90th percentile | vs 15 ppb action level |
|---|---|---|
| 2022-01-01 → 2024-12-31 | 4.18 ppb | Well below the 15 ppb action level |
| 2019-01-01 → 2021-12-31 | 4.9 ppb | Well below the 15 ppb action level |
| 2016-01-01 → 2018-12-31 | 6.82 ppb | Below the action level, but detectable |
| 2013-01-01 → 2015-12-31 | 2.63 ppb | Well below the 15 ppb action level |
| 2010-01-01 → 2012-12-31 | 3.86 ppb | Well below the 15 ppb action level |
| 2007-01-01 → 2009-12-31 | 2.3 ppb | Well below the 15 ppb action level |
| 2006-01-01 → 2008-12-31 | 1 ppb | Well below the 15 ppb action level |
| 2003-01-01 → 2005-12-31 | 0 ppb | Well below the 15 ppb action level |
| 2003-01-01 → 2003-06-30 | 1 ppb | Well below the 15 ppb action level |
| 2001-07-01 → 2001-12-31 | 1 ppb | Well below the 15 ppb action level |
| 2000-07-01 → 2000-12-31 | 1 ppb | Well below the 15 ppb action level |
| 1999-07-01 → 1999-12-31 | 1 ppb | Well below the 15 ppb action level |
Source: ECHO SDWA bulk download (SDWA_LCR_SAMPLES.csv, SDWIS 2026Q2, file dated 2026-07-09, fetched 2026-09-06)
EPA UCMR5 monitoring, 2024-08-05 to 2025-05-27 · 609 PFAS results at entry points to the distribution system
PFOA and PFOS measured at or above EPA's legal limit in at least one sample. Utilities have until 2029 (2031 under EPA's proposed extension) to comply with the 2024 PFAS rule, so a result above the MCL today is not yet a violation — but it is the number that matters for your health.
| Compound | Detects / samples | Max (ppt) | Reporting limit | EPA MCL |
|---|---|---|---|---|
| PFOA | 21 / 21 | 44 | 4 ppt | 4 ppt |
| PFOS | 10 / 21 | 5.7 | 4 ppt | 4 ppt |
| PFHxS | 11 / 21 | 7.1 | 3 ppt | 10 ppt |
| PFNA | 0 / 21 | < 4 | 4 ppt | 10 ppt |
| HFPO-DA | 0 / 21 | < 5 | 5 ppt | 10 ppt |
| PFBS | 11 / 21 | 5.8 | 3 ppt | hazard index only |
| PFBA | 13 / 21 | 6.5 | 5 ppt | hazard index only |
| PFHpA | 9 / 21 | 7.3 | 3 ppt | hazard index only |
| PFHxA | 12 / 21 | 7.8 | 3 ppt | hazard index only |
| PFPeA | 13 / 21 | 7.7 | 3 ppt | hazard index only |
“< 4 ppt” means below the laboratory reporting limit, not zero. ppt = parts per trillion (ng/L). Results are for finished water leaving the treatment plant.
Lithium (also monitored under UCMR5, not a PFAS): detected in 5 of 21 samples, max 13 µg/L. There is no federal limit for lithium.
What PFAS are and how to remove them → · Best filters for PFAS →
Source: UCMR5 occurrence data, EPA Data Summary July 2026 (UCMR5_All.txt)
EPA Six-Year Review 4 compliance samples for LIVINGSTON TWP DIV OF WATER · finished water only · dated data, released 2024
These are the regulated-contaminant samples LIVINGSTON TWP DIV OF WATER reported to its state between 2012 and 2019 — the most recent nationwide sample-level dataset EPA has published. Total trihalomethanes (TTHM), Haloacetic acids (HAA5) are flagged below; the status column explains why. Treat this as history, not today's tap water.
| Contaminant | Samples | Average | Max | EPA limit | Status |
|---|---|---|---|---|---|
| Arsenic | 216 detects | 0.354 µg/L | 2.2 µg/L | 10 µg/LMCL | Within MCL |
| Nitrate (as N) | 6967 detects | 1.739 mg/L | 3.98 mg/L | 10 mg/LMCL | Within MCL |
| Fluoride | 219 detects | 0.036 mg/L | 0.154 mg/L | 4 mg/LMCL | Within MCL |
| Chromium (total) | 2119 detects | 1.544 µg/L | 3.66 µg/L | 100 µg/LMCL | Within MCL |
| Uranium (combined) | 1211 detects | 2.006 µg/L | 4.05 µg/L | 30 µg/LMCL | Within MCL |
| Radium-226/228 | 120 detects | 0 pCi/L | ND | 5 pCi/LMCL | Not detected |
| Gross alpha | 1110 detects | 4 pCi/L | 8.4 pCi/L | 15 pCi/LMCL | Within MCL |
| Total trihalomethanes (TTHM) | 137136 detects | 31.171 µg/L | 98.1 µg/L | 80 µg/LMCL (LRAA) | 4 single samples over MCL; average within limit |
| Haloacetic acids (HAA5) | 137111 detects | 14.483 µg/L | 65.3 µg/L | 60 µg/LMCL (LRAA) | 1 single sample over MCL; average within limit |
| Lead (tap samples) | 9526 detects | 2.122 µg/L | 71 µg/L | 15 µg/Laction level (90th percentile) | Reported, not scored (compliance is on the 90th percentile) |
| Copper (tap samples) | 11673 detects | 54.037 µg/L | 445 µg/L | 1300 µg/Laction level (90th percentile) | Reported, not scored (compliance is on the 90th percentile) |
Averages count non-detects as zero. TTHM and HAA5 limits are locational running annual averages, so a single high sample is not a violation — we grade those on the average only. Lead and copper rows are individual tap samples and are shown for context; compliance (and our score) uses the 90th-percentile result above. LRAA = locational running annual average; ND = not detected.
Source: SYR4 Six-Year Review compliance monitoring data 2012–2019 (released 2024-03)
A point-of-use (under-sink) system typically runs $200-$600 installed; whole-house treatment $1,000-$3,000+ depending on flow and what has to come out. Tell us where you are and a certified water-treatment installer serving Livingston Township will follow up - no obligation.
Surface-water systems draw from rivers, lakes or reservoirs and must filter and disinfect, which is why disinfection byproducts (TTHM, HAA5) are the readings to watch.
How to test your tap water and the treatment options that actually fit Livingston Township homes
The most reliable way to know what is actually coming out of your tap is a certified mail-in lab test. City-wide EPA data (like the report above) reflects the water leaving the treatment plant, but contaminants such as lead and copper can be picked up from your own service line and household plumbing — so the water at your Livingston Township faucet can differ from the system average. A state-certified lab measures dozens of contaminants at once with results you can trust; you can also find one near you through the EPA's certified-lab list at epa.gov/dwlabcert. Hardware-store test strips are cheaper and instant, but they only screen for a few basics (chlorine, hardness, pH, and a rough lead pass/fail) and are far less accurate — treat them as a first look, not a diagnosis.
Match the treatment to what your test finds. Reverse osmosis (RO) removes the widest range of contaminants — lead, arsenic, nitrate, PFAS, and dissolved solids — which makes an under-sink reverse osmosis system the most thorough choice for Livingston Township households with heavy-metal or PFAS concerns. If your main issue is taste, odor, or chlorine, an activated carbon filter (pitcher, faucet, or under-sink) is simpler and cheaper and handles chlorine and many organic compounds well, though carbon alone does not remove arsenic, nitrate, or most PFAS. NSF-certified pitchers rated for lead reduction are the easiest way to start today while you decide on a permanent setup.
We may earn a commission from testing kits and filters purchased through these links, at no extra cost to you.
What Livingston Township residents measured at their own tap. All reader results →
Reader submissions are unverified and shown separately from EPA data. They reflect one tap on one day, not the utility's compliance record.
No reader results for Livingston Township yet - yours would be the first. A hardness or TDS number from a $10 strip kit is enough to start the map.
Help build the first reader-sourced water map. Enter whatever your test strip, TDS pen or lab report shows - one number is enough.
Livingston Township ranks #110 of 155 graded New Jersey cities.
Deep-dive guides for the specific contaminants EPA data flagged in Livingston Township's water, with removal options for each.
Livingston Township, NJ tap water is legal to drink but grades D on EPA's records, mainly because of PFOA or PFOS measured at or above the 4 ppt federal limit in 2023–2025 EPA sampling. A certified filter matched to that finding is a reasonable precaution.
LIVINGSTON TWP DIV OF WATER's most recent Lead and Copper Rule result (2022-01-01 to 2024-12-31) was 4.18 ppb at the 90th percentile, below EPA's 15 ppb action level. Because lead usually comes from service lines and household plumbing, homes built before 1986 should still test at the tap.
Yes. EPA's UCMR5 sampling (2024-08-05 to 2025-05-27) detected PFBA, PFBS, PFHpA, PFHxA, PFHxS, PFOA, PFOS, PFPeA, with PFOA or PFOS at or above the 4 ppt federal MCL. Reverse osmosis and certified activated-carbon filters reduce PFAS.
LIVINGSTON TWP DIV OF WATER has 37 violations on file since 2016: 0 health-based in the last five years and 9 monitoring or reporting violations in that window. Monitoring violations are paperwork lapses, not measured contamination.
LIVINGSTON TWP DIV OF WATER reports purchased surface water as its primary source and serves about 27,391 people (EPA PWSID NJ0710001).
We recommend one. Reverse osmosis or a PFAS-certified carbon filter addresses the PFAS result.
PFOA or PFOS was measured at or above EPA's 4 ppt limit in Livingston Township's UCMR5 sampling.
Most Popular for PFAS
Waterdrop 3-Stage Under-Sink
Lab-tested against PFAS "forever chemicals" — installs under the sink in minutes and costs far less than RO.
Check Price on AmazonCompare direct from Waterdrop
Reverse osmosis systems for PFAS
Reverse osmosis is the most thorough filtration class against PFAS — browse Waterdrop RO systems and check each model’s own tested claims.
Shop Reverse Osmosis Systems →Whole-Home Filtration System
Whole-house system — treats every tap at the source
For consistently poor water, a whole-home system filters every faucet, shower, and appliance — the permanent, install-once fix that goes beyond a single point-of-use filter.
Explore Whole-Home SystemsNot sure what filter you need?
Test your tap water first, so you filter for what's actually in it.
Shop Home Water Test Kits →We may earn a commission from Amazon and Waterdrop when you purchase through our links, at no extra cost to you.
Based on contaminants detected in your water, these resources may be helpful:
Find the right filter for your Livingston Township water quality needs:
Understand your water better with our in-depth guides on contaminants, filtration, and water safety.