Not health advice. Contact your local water utility for concerns.
Data from EPA Water Quality Reports. For official information, contact your water utility or health department.
EPA records for HUTCHINSON, CITY OF • Updated September 2026
Grade B — based on EPA compliance records, lead testing and PFAS monitoring
HUTCHINSON, CITY OF is in good standing with EPA, with only minor deductions for monitoring paperwork, low-level PFAS or historical readings near a limit.
Yes — by EPA's records Hutchinson, KS tap water is safe to drink and earns a B. The grade rests on 1 health-based EPA violation in the last five years. Lead from your own service line or plumbing is the main risk city-level data cannot see, so homes built before 1986 should still test at the tap.
Yes — by EPA's records Hutchinson, KS tap water is safe to drink and earns a B. The grade rests on 1 health-based EPA violation in the last five years. Lead from your own service line or plumbing is the main risk city-level data cannot see, so homes built before 1986 should still test at the tap.
HUTCHINSON, CITY OF's most recent Lead and Copper Rule result (2022-01-01 to 2024-12-31) was 0 ppb at the 90th percentile, below EPA's 15 ppb action level. Because lead usually comes from service lines and household plumbing, homes built before 1986 should still test at the tap.
No. None of the 58 UCMR5 PFAS results for HUTCHINSON, CITY OF (2024-04-09 to 2024-09-17) were at or above the reporting limit of roughly 3–5 ppt.
HUTCHINSON, CITY OF has 2 violations on file since 2016: 1 health-based in the last five years and 1 monitoring or reporting violation in that window. Monitoring violations are paperwork lapses, not measured contamination.
HUTCHINSON, CITY OF reports groundwater as its primary source and serves about 39,712 people (EPA PWSID KS2015509).
We recommend one. Check which contaminant the violations involved (table above) and choose a filter certified for it.
Compare filter options for your Hutchinson tap water
HUTCHINSON, CITY OF has 1 health-based EPA violation in the last five years.
Unsure which contaminants to treat? Compare home kits and certified lab testing before buying.
Amazon. We may earn a commission, at no extra cost to you.
HUTCHINSON, CITY OF · SDWIS records since 2016 · 5-year window starts 2021-09-13
EPA records 1 health-based violation for this system in the last five years, all of which are marked resolved or archived. Health-based violations mean a contaminant exceeded its Maximum Contaminant Level (MCL) or a required treatment step was not met.
| Violation | Category | Compliance period | Status |
|---|---|---|---|
| Treatment Technique (SWTR and GWR)Groundwater Rule | Treatment technique | 2022-06-01 → 2022-06-30 | Resolvedreturned 2022-06-30 |
| Notification, Known or Potential LSLLEAD AND COPPER RULE REVISIONS | Reporting | 2025-07-02 | Unaddressed |
Source: ECHO SDWA bulk download (SDWA_VIOLATIONS_ENFORCEMENT.csv, SDWIS 2026Q2, file dated 2026-07-09, fetched 2026-09-13)
EPA Lead and Copper Rule 90th-percentile results reported by HUTCHINSON, CITY OF
Well below the 15 ppb action level. In the most recent monitoring period on file (2022-01-01 to 2024-12-31), 90% of the homes HUTCHINSON, CITY OF sampled had lead at or below 0 ppb.
EPA's action level is 15 ppb (dropping to 10 ppb under the 2024 Lead and Copper Rule Improvements). There is no safe level of lead; the 90th-percentile figure describes the system, not your tap — homes with lead service lines or pre-1986 plumbing can be higher.
| Monitoring period | Lead 90th percentile | vs 15 ppb action level |
|---|---|---|
| 2022-01-01 → 2024-12-31 | 0 ppb | Well below the 15 ppb action level |
| 2019-01-01 → 2021-12-31 | 1.6 ppb | Well below the 15 ppb action level |
| 2016-01-01 → 2018-12-31 | 2 ppb | Well below the 15 ppb action level |
| 2013-01-01 → 2015-12-31 | 2.2 ppb | Well below the 15 ppb action level |
| 2012-07-01 → 2012-12-31 | 0 ppb | Well below the 15 ppb action level |
| 2012-01-01 → 2012-12-31 | 3.4 ppb | Well below the 15 ppb action level |
| 2012-01-01 → 2012-06-30 | 0 ppb | Well below the 15 ppb action level |
| 2011-01-01 → 2011-12-31 | 3.1 ppb | Well below the 15 ppb action level |
| 2011-07-01 → 2011-12-31 | 0 ppb | Well below the 15 ppb action level |
| 2010-07-01 → 2010-12-31 | 0 ppb | Well below the 15 ppb action level |
| 2010-07-01 → 2010-12-31 | 1.8 ppb | Well below the 15 ppb action level |
| 2010-01-01 → 2010-06-30 | 0 ppb | Well below the 15 ppb action level |
Copper 90th percentile: 1.4 mg/L (2005-01-01 → 2007-12-31); action level 1.3 mg/L.
Source: ECHO SDWA bulk download (SDWA_LCR_SAMPLES.csv, SDWIS 2026Q2, file dated 2026-07-09, fetched 2026-09-13)
EPA UCMR5 monitoring, 2024-04-09 to 2024-09-17 · 58 PFAS results at entry points to the distribution system
No PFAS detected. None of the 58 UCMR5 PFAS results for HUTCHINSON, CITY OF were at or above the method reporting limit. Reporting limits are about 3–5 ppt, so “not detected” means below that threshold — not proven zero.
| Compound | Detects / samples | Max (ppt) | Reporting limit | EPA MCL |
|---|---|---|---|---|
| PFOA | 0 / 2 | < 4 | 4 ppt | 4 ppt |
| PFOS | 0 / 2 | < 4 | 4 ppt | 4 ppt |
| PFHxS | 0 / 2 | < 3 | 3 ppt | 10 ppt |
| PFNA | 0 / 2 | < 4 | 4 ppt | 10 ppt |
| HFPO-DA | 0 / 2 | < 5 | 5 ppt | 10 ppt |
| PFBS | 0 / 2 | < 3 | 3 ppt | hazard index only |
“< 4 ppt” means below the laboratory reporting limit, not zero. ppt = parts per trillion (ng/L). Results are for finished water leaving the treatment plant.
Lithium (also monitored under UCMR5, not a PFAS): detected in 2 of 2 samples, max 13.7 µg/L. There is no federal limit for lithium.
What PFAS are and how to remove them →
Source: UCMR5 occurrence data, EPA Data Summary July 2026 (UCMR5_All.txt)
EPA Six-Year Review 4 compliance samples for HUTCHINSON, CITY OF · finished water only · dated data, released 2024
These are the regulated-contaminant samples HUTCHINSON, CITY OF reported to its state between 2012 and 2019 — the most recent nationwide sample-level dataset EPA has published. Every scored contaminant stayed within its Maximum Contaminant Level (MCL) and averaged below 80% of the limit. Treat this as history, not today's tap water.
| Contaminant | Samples | Average | Max | EPA limit | Status |
|---|---|---|---|---|---|
| Arsenic | 30 detects | 0 µg/L | ND | 10 µg/LMCL | Not detected |
| Nitrate (as N) | 11 | 1.964 mg/L | 2.6 mg/L | 10 mg/LMCL | Within MCL |
| Fluoride | 3 | 0.267 mg/L | 0.35 mg/L | 4 mg/LMCL | Within MCL |
| Chromium (total) | 32 detects | 1.133 µg/L | 2 µg/L | 100 µg/LMCL | Within MCL |
| Radium-226/228 | 1 | 0.4 pCi/L | 0.4 pCi/L | 5 pCi/LMCL | Within MCL |
| Total trihalomethanes (TTHM) | 70 | 25.447 µg/L | 69 µg/L | 80 µg/LMCL (LRAA) | Within MCL |
| Haloacetic acids (HAA5) | 7064 detects | 6.369 µg/L | 23 µg/L | 60 µg/LMCL (LRAA) | Within MCL |
| Lead (tap samples) | 9631 detects | 0.801 µg/L | 13 µg/L | 15 µg/Laction level (90th percentile) | Reported, not scored (compliance is on the 90th percentile) |
| Copper (tap samples) | 9694 detects | 160.067 µg/L | 1200 µg/L | 1300 µg/Laction level (90th percentile) | Reported, not scored (compliance is on the 90th percentile) |
Averages count non-detects as zero. TTHM and HAA5 limits are locational running annual averages, so a single high sample is not a violation — we grade those on the average only. Lead and copper rows are individual tap samples and are shown for context; compliance (and our score) uses the 90th-percentile result above. LRAA = locational running annual average; ND = not detected.
Source: SYR4 Six-Year Review compliance monitoring data 2012–2019 (released 2024-03)
A point-of-use (under-sink) system typically runs $200-$600 installed; whole-house treatment $1,000-$3,000+ depending on flow and what has to come out. Tell us where you are and a certified water-treatment installer serving Hutchinson will follow up - no obligation.
HUTCHINSON, CITY OF · 16,594 service lines inventoried · Q2 2026 snapshot
HUTCHINSON, CITY OF reports 16,594 service lines that are lead or galvanized-requiring-replacement (100% of the lines it has inventoried). A lead service line is the pipe between the water main and a building, so treated water can pick up lead after it leaves the plant — which city-level testing does not capture. Under EPA's Lead and Copper Rule Improvements, utilities must replace lead lines within 10 years starting in 2027.
Source: EPA SDWIS Service Line Inventory (Q2 2026) · PWS ID KS2015509 · See all Kansas lead service lines. We may earn a commission from filters and test kits, at no extra cost to you.
Groundwater systems draw from wells; naturally occurring arsenic, nitrate, radium and uranium are the readings to watch, along with PFAS near industrial or military sites.
How to test your tap water and the treatment options that actually fit Hutchinson homes
The most reliable way to know what is actually coming out of your tap is a certified mail-in lab test. City-wide EPA data (like the report above) reflects the water leaving the treatment plant, but contaminants such as lead and copper can be picked up from your own service line and household plumbing — so the water at your Hutchinson faucet can differ from the system average. A state-certified lab measures dozens of contaminants at once with results you can trust; you can also find one near you through the EPA's certified-lab list at epa.gov/dwlabcert. Hardware-store test strips are cheaper and instant, but they only screen for a few basics (chlorine, hardness, pH, and a rough lead pass/fail) and are far less accurate — treat them as a first look, not a diagnosis.
Match the treatment to what your test finds. Reverse osmosis (RO) removes the widest range of contaminants — lead, arsenic, nitrate, PFAS, and dissolved solids — which makes an under-sink reverse osmosis system the most thorough choice for Hutchinson households with heavy-metal or PFAS concerns. If your main issue is taste, odor, or chlorine, an activated carbon filter (pitcher, faucet, or under-sink) is simpler and cheaper and handles chlorine and many organic compounds well, though carbon alone does not remove arsenic, nitrate, or most PFAS. NSF-certified pitchers rated for lead reduction are the easiest way to start today while you decide on a permanent setup.
We may earn a commission from testing kits and filters purchased through these links, at no extra cost to you.
What Hutchinson residents measured at their own tap (ZIPs 67501, 67502). All reader results →
Reader submissions are unverified and shown separately from EPA data. They reflect one tap on one day, not the utility's compliance record.
No reader results for Hutchinson yet - yours would be the first. A hardness or TDS number from a $10 strip kit is enough to start the map.
Help build the first reader-sourced water map. Enter whatever your test strip, TDS pen or lab report shows - one number is enough.
Hutchinson ranks #14 of 20 graded Kansas cities.
Deep-dive guides for the specific contaminants EPA data flagged in Hutchinson's water, with removal options for each.
Yes — by EPA's records Hutchinson, KS tap water is safe to drink and earns a B. The grade rests on 1 health-based EPA violation in the last five years. Lead from your own service line or plumbing is the main risk city-level data cannot see, so homes built before 1986 should still test at the tap.
HUTCHINSON, CITY OF's most recent Lead and Copper Rule result (2022-01-01 to 2024-12-31) was 0 ppb at the 90th percentile, below EPA's 15 ppb action level. Because lead usually comes from service lines and household plumbing, homes built before 1986 should still test at the tap.
No. None of the 58 UCMR5 PFAS results for HUTCHINSON, CITY OF (2024-04-09 to 2024-09-17) were at or above the reporting limit of roughly 3–5 ppt.
HUTCHINSON, CITY OF has 2 violations on file since 2016: 1 health-based in the last five years and 1 monitoring or reporting violation in that window. Monitoring violations are paperwork lapses, not measured contamination.
HUTCHINSON, CITY OF reports groundwater as its primary source and serves about 39,712 people (EPA PWSID KS2015509).
We recommend one. Check which contaminant the violations involved (table above) and choose a filter certified for it.
HUTCHINSON, CITY OF has 1 health-based EPA violation in the last five years.
For Everyday Peace of Mind
Brita Elite Pitcher
Your water already tests well — a simple carbon filter improves taste and catches trace contaminants.
Check Price on AmazonNot sure what filter you need?
Test your tap water first, so you filter for what's actually in it.
Shop Home Water Test Kits →We may earn a commission from Amazon and Waterdrop when you purchase through our links, at no extra cost to you.
Find the right filter for your Hutchinson water quality needs:
Tap water is one piece of the picture — our sister sites cover the rest for Hutchinson, KS.
County radon prediction and EPA zone for homes around Hutchinson.
Arsenic and nitrate risk for homes on a well instead of city water.
Understand your water better with our in-depth guides on contaminants, filtration, and water safety.